Allow Joins

Enable joining at both ends of selected Revit walls in one operation.

Allow Joins enables wall joining at both ends of every selected Wall. It is useful when joins were previously disabled and you want Revit to reconnect the wall ends according to its normal join behavior.

Find the command in BIMO > Model > Allow Joins.

When To Use It

  • Restore normal wall joining after using Disallow Joins.

  • Re-enable joins for several walls at once.

  • Prepare wall intersections for further cleanup with standard Revit join controls.

Requirements

  • An active Revit project document is required.

  • The command processes Wall instances only.

  • You can preselect walls before launching the command or pick them after launch.

  • Walls in linked Revit models are not processed.

How To Use It

With Preselected Walls

  1. Select one or more Walls in the current project.

  2. Run BIMO > Model > Allow Joins.

  3. BIMO enables joining at both ends of every valid selected Wall.

Other preselected element types are ignored.

Without Preselection

  1. Run BIMO > Model > Allow Joins.

  2. In the Revit picker, select one or more Walls.

  3. Finish the selection.

  4. BIMO enables joining at both ends of the selected Walls.

The picker accepts Wall instances only.

Result

For every selected Wall, BIMO calls Revit's standard join operation for end 0 and end 1. The changes are applied in one transaction named Allow Wall Joins.

The exact geometry after the command is controlled by Revit. Enabling joins allows Revit to reconnect compatible wall ends, but it does not guarantee a particular cleanup order or intersection shape.

Progress And Cancellation

For larger selections, BIMO may show a progress indicator unless progress bars are disabled in general settings. Canceling the operation rolls back the active transaction, so partially processed walls are not kept.

Warnings And Model Impact

  • The command modifies the model by changing the join permission at both ends of each Wall.

  • Existing intersection cleanup may change after joins are enabled.

  • Review important wall intersections after running the command.

  • The command does not join non-wall elements and does not use Revit's Join Geometry tool.

Settings, Presets And Variants

Allow Joins has no command-specific settings and does not provide preset variants.

Troubleshooting

Problem

What To Check

The picker opens although elements were preselected

The initial selection contained no valid Wall instances.

Some preselected elements are ignored

Only Wall instances are supported.

The intersection still does not clean up as expected

Check wall location lines, heights, constraints, join order and whether the wall ends physically meet.

Linked walls are not changed

Open the linked model and run the command there.

Nothing changes visually

The wall ends may already allow joins, or Revit may keep the same cleanup result.

Known Limitations

  • Processes host-document Wall instances only.

  • Always affects both ends of each selected Wall.

  • Does not expose join order or intersection configuration.

  • Does not force walls to move or extend so that their ends meet.